E12-6 REVISED OCTOBER, 2018 © Copyright 2023. All rights reserved. No portion may be copied or reproduced in any manner. CONNECTORS ELECTRICAL FASTENERS SOSMETAL PRODUCTS INC. E15 E14 E13 E12 E11 E10 EXISTING METHODS: WIRE NUT END CAP How to read chart for 210675 One #16 Stranded plus three #22 Stranded (equaling four wires) can be connected using a 210675 connector. Part No. 210675 Blue Part No. 210676 Yellow Tubing has an active adhesive that seals multiple wires and eliminates wire pull-out Closed-end connectors are crimped here. In environments where corrosion and/or vibration are a problem, the closed-end connector can be used to replace wire nuts. How to read chart for 210676 One #12 Stranded plus three #18 Stranded (equaling four wires) can be connected using a 210676 connector. 22 1 • • • STR 2 •• 3 • 22 1 • • • • • • SOL 2 •• •• 3 • • 20 1 • • • • • • • • • SOL 2 •• •• •• 3 • • • 20 1 • • • • • • • • • • • SOL 2 •• •• • • • 3 • • • • 18 1 • • • • • • • • • • • STR 2 • • 18 1 • • • • • • • • • • • • • SOL 2 • • • • 16 1 ••• •• • • • • STR 2 16 1•• •••• SOL 2 14 1 • • • STR 2 1 2 3 1 2 3 1 2 3 1 2 3 1 2 1 2 1 2 22 22 20 20 18 18 16 STR SOL STR SOL STR SOL STR 18 1 • • • STR 2 •• 3 • 18 1 • • • • • • SOL 2 •• •• 3 • • 16 1 • • • • • • • • • SOL 2 •• •• •• 3 • • • 16 1 • • • • • • • • • • • SOL 2 •• •• • • • 3 • • • • 14 1 • • • • • • • • • • • STR 2 • • 14 1 • • • • • • • • • • • • • SOL 2 • • • • 12 1 ••• •• • • • • STR 2 12 1•• •••• SOL 2 10 1 • • • STR 2 1 2 3 1 2 3 1 2 3 1 2 3 1 2 1 2 1 2 18 18 16 16 14 14 12 STR SOL STR SOL STR SOL STR 1. Using the chart below, select the proper size of connector for the wires to be joined. A maximum of four wires may be connected. 2. Strip each wire 5/8”. 3. Insert all wires into the connector, make sure that each wire is properly seated and crimp the connector using an insulated connector crimping nest that matches the color dash on the heat shrink tubing. 4. Apply heat evenly to the tubing until the tubing fully recovers and the adhesive flows. DO NOT heat the crimp area since this will burn the plastic portion of the connector. During the heating process, separate the wires to allow the adhesive to flow in between the wires. 5. Remove from the heat and let cool. For best results, use a heat device of at least 400°F. When using an open flame, do not isolate the flame on one area of tubing. Distribute the heat evenly. Overheating the connector may cause damage to the tubing. Rating: 105°C • 600V maximum building wire • 1000V maximum in signs and fixtures • To be sold only with installation instructions • Not for use with multiple power sources. CLOSED-END CONNECTOR INSTRUCTIONS PROBLEMS: SOLUTION: SEALED MULTIPLE WIRE CONNECTORS: CLOSED-END CONNECTOR CLOSED-END CONNECTORS Joins two to four wires. PART NUMBER QTY WIRE GAUGE TUBING COLOR 210675 (50) 22-14 AWG Clear / Blue Dashes 210676 (50) 18-10 AWG Clear / Yellow Dashes
RkJQdWJsaXNoZXIy MzE1MDc=