Sosmetal Products, Inc. - 2023 Product Catalog

TEST TYPICAL PROPERTY METHOD PERFORMANCES Physical • Tensile strength ASTM D412, ISO 37 2100 psi (14.5MPa) • Elongation ASTM D412, ISO 37 600% • Elongation after heat aging (168 hrs. at 150° C) ASTM D2671 500% • Heat shock (4 hrs. at 225° C) ASTM D2671 No cracking or flowing • Longitudinal change ASTM D2671 +1%, -10% • Low temperature flexibility (4 hrs. at -55° C) ASTM D2671 No cracking • Specific gravity ASTM D792 1.1 • Hardness (Shore D) ASTM D2240 50D Electrical • Dielectric strength ASTM D149 500 V/Mil (20kV/mm) • Dielectric voltage withstand UL 486D No breakdown, (2500 V, 60Hz, 1 Min.) 24kV – 1 min., 15kV – 4 hrs. • Volume resistivity ASTM D257 1016 ohm-cm TEST TYPICAL PROPERTY METHOD PERFORMANCES Chemical • Fluid resistance MIL-DTL-23053 Good to excellent • Fungus resistance ASTM G21 No growth • Copper corrosion ASTM D2671 No corrosion • Water absorption ASTM D570 0.1% Adhesive • Adhesive lap sheer ASTM D1002 125 psi (.875 MPa) (1 in./min. at 23° C) • Adhesive softening point ASTM E28 92° C ±5° C • Adhesive peel strength ASTM D1000 (300mm/min. at 23° C) — to steel, aluminum, P.E. 35 pli — PVC 20 pli • Water penetration STM 706 No penetration after 236 hrs. of continuous immersion HS SERIES SPECIFICATIONS Shrink-Kon® – Heat Shrinkable Insulators E14-5 REVISED MARCH, 2021 © Copyright 2023. All rights reserved. No portion may be copied or reproduced in any manner. SOSMETAL PRODUCTS INC. ELECTRICAL FASTENERS E10 E11 E12 E13 E14 E15 SHRINK-KON® HS SERIES - HEAVY WALL HEAT SHRINKABLE TUBING • Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced. • Withstands severe mechanical requirements of U.R.D., submersible, and direct burial installations. • Tubing, featuring an internally applied sealant, offers protection against moisture, and may be used over lead, steel, aluminum, copper, standard plastic and elastomeric insulating materials. • Shrink temperature of 120° C. • High-impact, abrasion, corrosion and chemical resistance. • Rated for 600V, 90° C continuous use. • Thermoplastic adhesive liner provides complete environmental protection and insulation. • Meets: UL® 486D, CSA C22.2 No. 198.2, ANSI C119.1, Western Underground Guide Numbers 2.4, 2.5, ICEA and NEMA insulation thickness requirements. • Continuous operating temperature: -55° C to 110° C. 3:1 SHRINK RATIO FITS ANY LISTED OR CERTIFIED MIN. MAX. NOM. AL OR CU SPLICE WITH DIM EXPANDED RECOVERED RECOVERED STD. NO LARGER THAN I.D. I.D. WALL LENGTH O.D. LENGTH CABLE PKG. CAT. NO. (IN.) (IN.) (IN.) (IN.) (IN.) (IN.) RANGE QTY. HS1612 .35 .12 .07 3 .27 1.00 #14 to #10 AWG 25 HS1612L .35 .12 .07 6 .27 1.00 #14 to #10 AWG 25 HS16124 .35 .12 .07 48 .27 1.00 #14 to #10 AWG 5 HS126 .51 .16 .09 3 .38 1.75 #8 to #6 AWG 25 HS126L .51 .16 .09 6 .38 1.75 #8 to #6 AWG 25 HS1264 .51 .16 .09 48 .38 1.75 #8 to #6 AWG 5 HS61 .75 .24 .09 4 .63 2.50 #6 to #2 AWG 25 HS61L .75 .24 .09 8 .63 2.50 #6 to #2 AWG 25 HS614 .75 .24 .09 48 .63 2.50 #6 to #2 AWG 5 HS430 1.10 .35 .12 5 .75 3.25 #1 to 3/0 AWG 20 HS430L 1.10 .35 .12 9 .75 3.25 #1 to 3/0 AWG 10 HS4304 1.10 .35 .12 48 .75 3.25 #1 to 3/0 AWG 5 HS40400 1.50 .47 .16 8 - - - - 2/0 to 350 MCM 10 HS40400L 1.50 .47 .16 12 - - - - 2/0 to 350 MCM 10 HS404004 1.50 .47 .16 48 - - - - 2/0 to 350 MCM 5 HS5001000 2.00 .63 .16 9 - - - - 250–500 MCM 5 HS5001000L 2.00 .63 .16 15 - - - - 250–500 MCM 2 HS50010004 2.00 .63 .16 48 - - - - 250–500 MCM 2 All lengths have factory-applied sealant. UL File No. E9809, UL 486D. HS SERIES HEAVY WALL HEAT SHRINKABLE BLACK TUBING HS SERIES HEAVY WALL HEAT SHRINKABLE RED TUBING MIN. MAX. FOR 2-WAY EXPANDED RECOVERED LGTH. CONNECTOR PKG. CAT. NO. I.D. (IN.) I.D. (IN.) (IN.) CABLE SIZES QTY. HS1612LR .35 .12 6 14-10 AWG 5 HS126LR .51 .16 6 8-6 AWG 5 HS61LR .75 .24 8 6-2 AWG 5 HS430LR 1.10 .35 9 1-3/0 AWG 10 HS40400LR 1.50 .47 12 2/0-350 MCM 5 HS5001000LR 2.00 .63 15 250-600 MCM 5 All lengths have factory applied sealant. U.L. File No. 9809, U.L. 486D

RkJQdWJsaXNoZXIy MzE1MDc=